I love all my my Doepfer A100 gear, it's what got me into modular in the first place!
Recently I noticed a bleed issue with my A132-3 Dual VCA.
It only seemed to happen in linear mode, and only with one channel. A post to the excellent Doepfer Yahoo group yielded a reply from Herr Doepfer himself.
"Hello,
V2 is an older version from 2010. Due to tolerances of the V2164D sometimes
the VCA does not close with CV=0. To avoid this a high value resistor (e.g.
4M7) has to be added between pin 4 (upper VCA) or pin 5 (lower VCA) of the
V2164 and -12V. This adds a small negative voltage to the CV summing
node. -12V is available e.g. at pin 9 of the V2164 or the wire bridge "J1"
below the V2164.
In V3 and V4 of the module the 4M7 resistors have been added.
Hope this helps
Dieter Doepfer"
A quick mod with two hefty 4M7 Resisitors and my Dual VCA closes to silence. Stuff like this makes realise why I love the modular scene.
I don't think many units with this problem were shipped, but I'm posting this just in case it might help any other folk...
Topside of my V2 unit
Underside of my unit with 2x 4M7 R's in place.
Job Done.
Job Done.